BATTERYDOC™
Wall Mount I
Battery Charger/Maintainer Part# SDS012-0001
Important: This document contains information
provided by Operating Technical Electronics, Inc.
Scope: This specification defines the performance
characteristics of a 12 volt 1.0A portable battery charger with
float mode charging. The specification also defines world wide
safety and operating requirements.
- Input Requirements
- Output Requirements
- M.T.B.F.
- Protection
- Electromagnetic Requirements
- Safety Requirements
- Environment
- Dimensions
|
|
|
INPUT REQUIREMENTS
- 100 VAC-240VAC ± 10% /47Hz to 63 Hz
input
- (a) 30A max. @ 115VAC under the worst case
load and cold start
- (b) 60A max. @ 230VAC under the worst case
load and cold start
- 0.5 RMS Max. at full load and 115 VAC input
- 0.25 RMS Max. at full load and 230 VAC input
- 70% min. at specified line voltages, outputs
at full load
The output shall be isolated from the input and
the supply shall be able to withstand without permanent damage.Power
line transients as defined in IEC 801-4 or IEC 801-5, line to
neutral 1 kV line to neutral with floating ground, 2kV.
OUTPUT REQUIREMENTS
- 1% measure at 115VAC or 230VAC±15%
- ±5% measure at all output from min.
load to max. load
at 115VAC ,60Hz.
M.T.B.F.
M.T.B.F. shall be a min. of 100,000 hours when
operated at
25 °C ambient, running at 100% duty cycle with the following
line and load conditions:
|
PROTECTION
- Electronically controlled
- Unit will sustain "No Damage" when connected with reverse battery polarity.
- For any output shorted to ground, grounded output will not damage this power supply. A short to the ground will be defined as a maximum of 0.1.
- Unit will sustain "No Damage" when connected with reverse battery polarity.
ELECTROMAGNETIC REQUIREMENTS
The radiated and conducted emissions of this adapter comply with the requirements of United States Federeal Communication Commission (FCC) part 15, class B and with CISPR 22.and CISPR 22.
SAFETY REQUIREMENTS
- The power supply is approved for the following:
- HI POT A: Primary - Secondary (FG) - 1500VAC for 60 seconds or DC equivalent 2121VDC for 60 seconds. If DC voltage used for test, the voltage should ramp up and down with 1 sec. rise time.
- HI POT B: Transformer Primary - Secondary - 3750VAC for 1 minute (component level).
- 4 hours at 40 ± 5°C, Nominal input voltage, 80% of maximum load
ENVIRONMENT
- (1) Operating temp. is 0 °C to 40°C.
- (2) Storage temp. is -20°C to 85° C.
- (3) Operating humidity is 15% to 85% RH
- (4) Storage humidity is 5% to 90% RH
DIMENSIONS & WEIGHT
- LxWxH: 104mm x 58mm x 31.8mm
- Weight: 240 g Typical
|